| No. |
Part |
description |
| 1 |
¡¡
|
Push to operate |
| 2 |
¡¡
|
Push to operate |
| 3 |
¡¡
|
Push to operate |
| 4 |
¡¡
|
Preset time and temperature |
| 5 |
¡¡
|
Increase
button |
| 6 |
¡¡
|
Decrease button |
| 7 |
¡¡
|
Change from centigrade to
Fahrenheit |
| 8 |
Time display window |
Display the rest work time of
the steam generator |
| 9 |
Temp display window |
Display the detected
temperature of steam room> |
| 10 |
L1 |
Indicator LED for the lamp of
steam room .it is on/off with the on/off of the lamp in steam room |
| 11 |
L2 |
Indicator LED for water level
.red means water is filling. green means water level arrived control
point.note:if the LED always in red (exceed 5 minutes).check water supply and
if water level valve is block .otherwise the water level inlet valve will be b |
| 12 |
L3 |
Indicator
LED for drain .red means is draining .green means drain and filling at the
same time> |
| 13 |
L4 |
Indicator LED for key-lock, when
the key-lock function is react. Red means the total work time achieved the
lock time .only unchain the lock ,the steam generator can work again (this
function is just some customer¡¯s request., only customer request ,we wil |
| 14 |
L5 |
Indicator LED for over heat ,red
means the steam generator was cut off as the heat element is too hot (lack of
water ,the heat elements may worked in air) |
| 15 |
L6 |
Indicator
LED for pressure .when the pressure in the boiler is exceed 1.2kg/c m2. ,it
will on |
| 16 |
L7 |
Indicator LED for heating . when
the detected temperature is lower than the temperature we preset .it is on
and means the steam generator is heating |
| 17 |
L8 |
Indicator LED for heat
preservation . when the detected temperature is higher than the temperature